ABSTRACT

The initial cost of the power inverter system is significant higher compared to the conventional source of power. As a result, there is need for the performance evaluation of various power inverters in order to determine the cost efficiency of the power inverter as an alternative source of power. The aim of the present study is to investigate the performance index of 3.5KVA/48V inverters for domestic source of electric power supply. Four types of inverters (Mercury, Safer Power, Sinergy and Su-Kam) commonly available in the market were considered. And three performance indices (resistive load test, inductive load test and output waveform) were used to determine the cost effectiveness of one inverter over the other. Results showed that the Sinergy Power Inverter has the best performance. In terms of the battery discharge current, Sinergy is 35% (for the resistive) and 61% (for inductive test) more efficient compared to Mercury at an output load of 1 kW.

 

 

CONTENT

Front Page                                                                                                                   i

Declaration                                                                                                                  ii

Certification                                                                                                                iii

Dedication                                                                                                                  iv

Acknowledgement                                                                                                      v

List of abbreviation and acronym                                                                               vi

Abstract                                                                                                                      viii

Content of contents                                                                                                    ix

chapter one

introduction

1.1       Background to the Study              1

1.2       Statement of the Problem                     3

1.3       Aim of the Study                4

1.4       Objectives of the Study              4

1.5       Methodology                  4

1.6       Scope of the Study                4

1.7       Significance of the Study              5

1.8       Arrangement of the Work              5

chapter two

literature review

2.1       Overview of Energy Conversion Techniques         6

2.2       Inverter           7

2.2.1   Classification of Inverter                                                                                 12

2.2.2    Advantages and Disadvantages of Inverter         13

2.2.3    Things to Consider Before Buying An Inverter       13

2.3       Batteries              17

2.3.1    Types of batteries             18

2.4      Inverter Battery Connection              20

2.5       State of the art          22

chapter three

methodology

3.1       Experimental Setup                24

Materials Used On Installation Experimentation          24

CHAPTER FOUR

RESULT AND DISCUSSION                     37

4.1       Inverter Load Test:       37

4.2       Sinergy Inverter Load Test           41

4.3       Safer-Power                      45

4.5       Bill of Engineering Measurement And Evaluation   53

CHAPTER FIVE.. 54

CONCLUSION AND RECOMMENDATION               54

5.2       RECOMMENDATION                     54

 

 

CHAPTER ONE

INTRODUCTION

1.1     Background to the Study

Electric power interruptions are quite common in every place, especially after a heavy down pour or a severe storm. To counter this power outage, a search has been to find a reliable and economical alternative source of electricity. Although this kind of project has been dealt with for quite a number of time but the fact still remains that an improvement needs to be done. This in essence makes the project topic “Investigation of the performance index of 3.5KVA/48V inverter” purposeful and resourceful.

        An inverter is a device or an electronic that converts or inverts a direct current into a conventional alternating current. A power inverter is a great tool used to run household / office appliances, where there is no electricity. The input voltage and frequency of the inverter may be fixed or it may vary depending on its application. Inverters finds several applications of which are the valuable speed, alternating current motors, uninterrupted power supply etc. They can be used as the front stage of dc to dc converter. Standby inverters are mostly used to provide emergency supply to the main frequency (50Hz). In the event of main failure, the inverter immediately operates with no loss of waveform. This unique ability makes it related to an automatic change over switch but it differs in a way in that it has a battery, which stores energy when the mains is on and gives out energy when the mains is off while the automatic change over switch operates on contactor (open and close).

         There are many types of inverter as described in chapter 2, but they all have the same principle of operations and it all depends on the component used, whether with a thyristor or a bipolar junction transistor for switching the current ON/OFF. The need for man to prevent his activities from being interrupted in order not to render it incomplete which may subsequently become an unfinished job (loss of files in the computer when there is a sudden power outage) has motivated engineers across the globe to design a device which will be more economical, durable and efficient.

It is pertinent to note that in a well organized company in a developing country like Nigeria, where a lot of transactions are made, if there is an epileptic power supply, the flow of transaction will greatly be hindered and there will be no open ground for the infant companies to spring up and wax great. Power should not be an obstruction between companies and their maximum profits, this in essence makes the use of a power inverter relevant and recommended to all and sundry. Hence, the need for the investigation of the performance index of various inverters comes to play. And this helps to determine which inverter is more efficient, portable, durable, and cost effective.

 

1.2     Statement of the Problem

The primary aim of engineers in the society is to solve the problems militating against technological growth, provide solutions to challenges facing humanities and bringing about efficient flow of ideals and innovators in the world of technology throughout the society and all nation of the earth. Inverter is that device which is being employed by the engineers to tackle and support the power supplies. This support comes to play when there is power outage. Immediately, the power inverter begins to act in place of the main power. Inverter are used in the conversion of direct current to a conventional alternating current, but the need for a reliable and more efficient, stable power supplies make the inverter indispensable especially in developing country like Nigeria where there is an epileptic power supply. Hence the need for investigation of the performance index of 3.5kVA/48V inverter in relation to other inverters becomes vital.

           Although, the electric power in an alternating current form is very difficult to store due to power loss which are associated with the alternating current and when converted, it can be in stored in the battery of which can be recharged.

1.3     Aim of the Study

The aim of the study is to evaluate the performance index of 3.5KVA/48V inverters for domestic electric power supply.

1.4     Objectives of the Study

                The objectives of the study are stated as follow.

  1. To determine the output wave form of the inverter
  2. To determine the battery discharging current/voltage on load and the effect of load on the inverter
  3. The determine the  power efficiency (real-time output power ratings)

1.5     Methodology

`        The methods adopted to achieve the set objectives are as follows.

  1. The Cathode ray oscilloscope was used to measure output wave form.
  2. The resistive and inductive load tests were applied to determine the battery discharging current/voltage on load and the effect of loads on the selected inverter
  3. Clamp meter, amp meter and volt meter were utilized.

1.6     Scope of the Study

In this study, the capacity of power inverters considered is 3.5KVA/48V with an output of 220-230V, frequency of 50Hz. And four different inverters vendors selected are Mercury, Safer power, Sinergy and Su-kam.  The choice of selection is based on the availability, portability, customer patronage and assesses to parts or repair.

1.7     Significance of the Study

          The study can enable:

  1. the individual to have basic knowledge  about inverter;
  2. the energy consumer decide on the most economic inverter to install
  3. create more awareness on the use of inverter.

1.8     Arrangement of the Work

The study is divided into five chapters. Chapter one has been discussed. Chapter two gives a description of power inverters and battery, and what to look out for before buying inverter.

Chapter three discussed the experimental setup of the 3.5KVA/48V inverters for various inverters, and how it was analysed. The arrangement is based on the selected load specification of 1000VA.

In chapter four, the results of the performance of various inverter used as a case study, were presented and discussed.

Chapter five gives the conclusion and recommendation of the study.


Get The Complete Project »

Project Department:

MORE ELECTRICAL ELECTRONICS ENGINEERING FREE UNDERGRADUATE PROJECT TOPICS AND RESEARCH MATERIALS

Instantly Share this Project On Social Media:

CLOSELY RELATED ELECTRICAL ELECTRONICS ENGINEERING FREE UNDERGRADUATE PROJECT TOPICS AND RESEARCH MATERIALS

SOLAR POWER INVERTERS, ANALYSIS AND TEST EVALUATION

 Format: MS WORD ::   Chapters: 1-5 ::   Pages: 100 ::   Attributes: EXPERIMENT  ::   16418 engagements

INTRODUCTION The quest to satisfy our need for stable power supply in Nigeria has driven most Nigerians into an ardent search for alternative renewable power sources. One of such major renewable power...Continue reading »

DESIGN AND CONSTRUCTION OF MICROCONTROLLER TIMER SOCKET OUTLET

 Format: MS WORD ::   Chapters: 1-5 ::   Pages: 71 ::   Attributes: EXPERIMENT  ::   4962 engagements

CHAPTER ONE INTRODUCTION BACKGROUND INFORMATION As the world becomes concerned with conserving electric power and the fuels that generate electricity, there is a growing need for the conscientio...Continue reading »

DESIGN AND CONSTRUCTION OF A SOLAR POWERED MULTIPLE CELL PHONES CHARGING BOOTH

 Format: MS WORD ::   Chapters: 1-5 ::   Pages: 56 ::   Attributes: EXPERIMENT  ::   6141 engagements

ABSTRACT Cell phones need electric sources to charge their batteries in order to work, but there are people in developing and third world countries that find it hard to access electric sources.In an ...Continue reading »

IMPROVING THE CAPACITY OF A RENEWABLE POWER SYSTEM, USING SOLAR POWER PANEL (A CASE STUDY OF COMPUTER SCIENCE ND SOFTTWARE LAB)

 Format: MS WORD ::   Chapters: 1-5 ::   Pages: 70 ::   Attributes: EXPERIMENT  ::   4379 engagements

CHAPTER ONE INTRODUCTION 1.1 BACKGROUND TO THE STUDY The use of renewable energy increased greatly just after the first big oil crisis in the late seventies. At that time, economic issues were the...Continue reading »

DESIGN OF A FULL ADDER CIRCUIT

 Format: MS WORD ::   Chapters: 1-5 ::   Pages: 35 ::   Attributes: EXPERIMENT  ::   5090 engagements

CHAPTER TWO 2.0 LITERATURE REVIEW According to the novel by Mehdi Ghasemi, Mohammad Hussein Moaiyeri, Keivan Navi, published on Jan 10, 2012. Due to high power consumption and difficulties with...Continue reading »

DESIGN OF INDUSTRIAL BATCH COUNTER

 Format: MS WORD ::   Chapters: 1-5 ::   Pages: 30 ::   Attributes: EXPERIMENT  ::   5271 engagements

CHAPTER ONE INTRODUCTION The industrial batch counter is an electronic and electrical device that handles the counting and controls the flow of individuals using an automated slide door that ...Continue reading »

What are you looking for today?

TESTIMONIALS:

  • 1. Jayone from FPA said " I had a wonderful experience using UniProjectMaterials,though they did not deliver the material on time, but the content had good quality. I recommend UniProjectMaterials for any project research work.".
    Rating: Very Good
  • 2. Mugisha R from B.U, UGANDA said "Wow, this is great, your materials has helped me alot. Many blessings. I will inform my friends. Thanks. ".
    Rating: Very Good
  • 3. Nwachukwu Ruth Chinyerr from Michael okpara university of Agriculture,umudike said "I really appreciate this. Materials like this are good guides to writing a researchable project.".
    Rating: Good
  • 4. Ibrahim Salama from Kaduna said "Thanks You So Much Sir We Appreciate ".
    Rating: Excellent
  • 5. Ibrahim Salama from Kaduna said "Thanks You So Much Sir We Appreciate ".
    Rating: Excellent
  • 6. Mohammed A.B from Veterinary Laboratory, Zanzibar ,Tanzania said "You are doing good job to assists in research. God bless you.".
    Rating: Very Good

Paper Information

Format:MS WORD
Chapter:1-5
Pages:75
Attribute:EXPERIMENT
Price:₦3,000
Get The Complete Project »

Best Selling Projects

Our Archives